Setting Reactions to Ransomware Attacks
In the Reaction To Attack screen, you can define two reactions to detected attacks, based on criteria set in the Threat Control Center screen, as shown in Setting Thresholds for Ransomware Detection.
To set the methods by which Anti-Ransomware responds to alerts of different levels, select 4. Reaction To Attack from the Anti-Ransomware main screen, as shown in Starting Anti-Ransomware.
The Reaction To Attack screen appears:
Reaction To Attack RLDEV Anti-Ransomware mode . . . . . Y Y=Yes, I=FYI, N=No *FYI* is an acronym for "For Your Information". Reaction Message to QSYSOPR . . . . . . Y Y=Yes Inform SIEM . . . . . . . . . Y=Yes Email system admin . . . . . . orenc In *FYI mode, the following is not performed. Stop attack of User from IP . Y Y=Yes End system wide File Server . Y=Yes Stops all remote access to shares. Hibernate/Shutdown attacker . Y=Yes See procedure and restrictions in SMZV/AVSOURCE ATP4RMT Submit/Call on this system . . S=Submit, C=Call Program . . . . . . . . . . Name Library . . . . . . . . . . Name *LIBL Program should be Thread Safe. See example program in SMZV/AVSOURCE ATPALERTR F3=Exit |
The body of the screen lists different possible reactions. You can also set further details and specifications for some of the reactions.
To choose that reaction, set the field in that column to Y (except as shown below). Otherwise, leave the field blank.
Possible reactions are:
Message to QSYSOPR
Send a system message to QSYSOPR.
Inform SIEM
Alert up to three SIEM systems as set from the iSecurity/Base System Configuration screen within the iSecurity Base System (STRAUD > 81). Additional information on SIEM support is available in the SIEM Support, Syslog Parameters, Triple Syslog Definitions (#1-#3), etc.
Email system admin
Send an email to the system administrator at the email address in this field.
Stop attack of user from IP
End the attack.
End system wide File Server
End all activity on the file server that is being attacked.
Hibernate/Shutdown infected PC
Hibernate or shutdown the PC with which the system is communicating.
See SMZV/AVSOURCE ATP4RMT for more information.
Submit/Call on this system
Set this to C to call the program or S to submit it. Enter the name and library of the program in the Program to run and Library fields, respectively.
See SMZV/AVSOURCE ATPALERTR for a sample program.